The app comes with premium functionalities, which you have to pay for; however, you can try the 60-day free trial to see how it works. The SRL2 detects changes in concentration of. In this case, using asecond hand to guide the tip along refrigerantlines may be helpful. Inhalation of high concentrations of refrigerant vapor can block oxygen to the brain causing injury or death. The tip of the wand should be fairly close to the. In previous articles, I have told you that finding refrigerant leakages using infrared technology is actually my favorite and most efficient method. BacklightPress to toggle the blue backlight. The unit is set to auto-zero by default, but if you need a fresh reading, you can perform a sort of "mini-calibration" by putting the meter in non-contaminated air and pressing the manual zero button. Because a heated diode detector like the SRL8 is made to detect these microscopic ions, it can detect very small refrigerant leaks accurately. Sign in to see current pricing and availability. Furthermore, The device is easy to use, and you can depend on it in various environments. When max mode is on, the highest leak size detected is continually recorded.The recorded max is cleared when the sensitivity is changed or if manually zeroed. SRL8 Fieldpiece Heated Diode Refrigerant Leak Detector - Rugged and Accurate. Zero SetIn manual zero mode (MZERO), press ZERO to initiate a 10 second calibration, during which Zeroing is displayed. You can bend the flexible probe numerous times to help you access the tightest joints and corners in your HVAC system. You will need to register the product upon purchase to activate the warranty. The SRL8 Heated Diode Refrigerant Leak Detector is designed exclusively to make the HVAC/R Technician's job easier, faster, safer and more efficient. Turbo is extremely sensitive, and may false trigger from abrupt motion or small changes in gas content. 1. The above limitations or exclusions may not apply to you. on Fieldpiece DR82 Infrared (IR) Refrigerant Leak Detector User Manual, Fieldpiece Vacuum Pump with RunQuick Oil Change System Owners Manual, Fieldpiece DR58 Heated Diode Refrigerant Leak Detector User Manual, Fieldpiece DR82 Infrared (IR) Refrigerant Leak Detector, INFICON D-TEK 3 Refrigerant Leak Detector User Guide, HydroCheck WaterWatcher Leak Detector User Guide, TRIPLETT GSM050 Gas Leak Detector User Manual, AJAX 8706 KeyPad Wireless Touch Keyboard User Manual, Meizhou Hongfeng Arts Crafts 266285 BJ 57IN Snowman With Snowflakes Instruction Manual, AJAX 7661 StreetSiren Wireless Outdoor Siren User Manual, AJAX 17938 12V PSU for Hub/Hub Plus/ReX Power Supply Unit User Manual, AJAX 10306 Transmitter Wired to Wireless Detector Converter User Manual, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual. Note, however, that its a common problem with most infrared units. Once the SRL2 indicates a change in concentra-, tion, note the spot on the line and keep the tipmoving past the potential leak to refresh the airspace within the SRL2 with clean air. 15-hour rechargeable lithium ion battery with wall and vehicle chargers. Its a durable piece of equipment that you can depend on for many years since its durable. You can order from a distributor extra bags of. We set out to develop the best refrigerant leak detector for HVACR. The unit wont have a problem detecting small leakages, even in tight spaces. A one-year warranty is relatively short for its price (about $500). Set the sensitivity level by pressing the L/M/H but-. Stays where you want it. The ruggedized construction stands up to abuse most other leak detectors can't handle. Confirm leak source. Work all day and all night on one charge, Battery life check. To pinpoint larger leaks adjust sensitivity. from the sensor. UV dyes can take several hours to travel through a running system and can degrade system components. Search until refrigerant gas is detected. ), 4. Fieldpiece also has a digital app (available for Android and iOS devices) that functions with all wireless tools. sales@jjstech.com, Copyright 2000-2021. RT175B Refrigeration Technologies Brush On Blu Leak Detector Bubbles 8oz. Useless on r22. | Details. We believe the SRL8 is it. Your email address will not be published. Apart from the sensor, it also comes with a durable body that can withstand all weather and conditions. The SRL2 uses an infrared (IR) sensor. The Fieldpiece SRL8 will recognize the presence of these ions and give off an audible beeping (if you choose) and a visual alarm, alerting you to leaking refrigerant gas. Rugged / Ergonomic Features. The vast majority of refrigerant gases that you'll encounter in the field contain Fluorine, Chlorine, or both. It help me for jobs analysis. Are Infrared Refrigerant Detectors Worth It? JJS Technical Services. You should see a very large leak size of approximately 99 and a full bar graph. concentration achieved while continuing to detectleaks. ON/OFF button for one second. If you accidentally hit some condensation or oil, the filter swells, shutting off the pull to the sensor and protecting it from failure. The SRL2 detects leaks as small as 0.1 oz/year. Sensor Type: Infrared (IR)Sensor Life: 10 years typicalSensitivity Levels: High, medium, low, turbo (selectable)Maximum Sensitivity: 0.03 oz/yr (1g/a), stationary; 0.1 oz/yr (3g/a), in motionDetection Feedback: Red tip LED, LCD bar graph, LCD digits, beeperRefrigerants: HFC, HCFC, CFC, HFOs, and blendsResponse Time: <1 seconds typicalRecovery Time: <5 seconds typicalBattery Type: 3.7 VDC (nominal) 2600mAh, non-replaceableCharge Time: 6 hours typical with included charger.Battery Life: 10 hours typical, backlight offAuto Power Off: 10 minutes without detection or button pressOperating Environment: 32F to 104F (0C to 40C); < 75% RH (non-condensing)Storage Temperature: -4F to 140F (-20C to 60C); < 80% RH Weight: 14 oz (400g)Water Resistance: Designed to IP54US Patent: www.fieldpiece.com/patents, DR82 Infrared Refrigerant Leak DetectorBlow Molded Carrying Case (ABM2)AC Charger and USB-C Cable (RCA3)5 x Filter Tips and Gaskets (RFT6)Operators Manual1 Year Limited Warranty. Peak / Mute Buttons. If you are not finding a leak, or are having trouble pinpointing it's location, then you can increase the sensitivity. Primarily, for me, its an infrared refrigerant leak detector. You can also enable an audible beeping sound to assist you. Meets new SAE standards. You are assured of getting all the benefits that a quality infrared leak detector would provide. 1-866-4 JJSTECH (1-866-455-7832) You can also use it while it's hooked up to the wall or vehicle charger. When Fluorine or Chlorine gases (HFCs, CFCs, and HCFCs) are exposed to heat, they break down and give off positive ions, hence the big name from above. This slight delayprotects against inadvertent pressing. Learn more about Email Subscription by visiting our FAQspage. Unscrew thesensor tip and replace the white filter so that therounded end is closest to the tip of the wand. Hang the unit while you repair the leak, Advanced Refrigerant Leak Detector - SRL8, (5) O-rings and 10 Replacement Filters - RFL2. Current slide {CURRENT_SLIDE} of {TOTAL_SLIDES}- Best Selling in HVAC & Refrigeration Leak Detectors, Current slide {CURRENT_SLIDE} of {TOTAL_SLIDES}- You may also like, {"modules":["unloadOptimization","bandwidthDetection"],"unloadOptimization":{"browsers":{"Firefox":true,"Chrome":true}},"bandwidthDetection":{"url":"https://ir.ebaystatic.com/cr/v/c1/thirtysevens.jpg","maxViews":4,"imgSize":37,"expiry":300000,"timeout":250}}. Works even in contaminated environments. This helps us keep compliant and prevents any and all future headaches for you or your company down the road. So, starting on LOW sensitivity, you want to begin "sniffing" in the location you expect to find a leak. Like most products from this brand, the device will not give you false alarms. ity that pushes the SRL2 to it highest possible sen-sitivity. Sometimes, the product may develop a problem after the one year is over. Open valve to coat the inside of the cap, then close the valve. Asthe concentration of refrigerant in the air increases,so does the number of lit bars on the display. One more quick tip: to ensure accuracy make sure that your SRL8 refrigerant leak detector is zeroing between samples. CLEANING: Clean the exterior with a damp cloth. At the top is a 17-inch flexible probe with a lighted LED tip, a replaceable filter, and a sensor that lasts up to 10 years. Meets new SAE standards. Fieldpiece SRL2K7 Advanced Refrigerant Leak Detector. The sensordetects changes in concentration, not absolute con-centration, making it easy to detect leaks even inareas with refrigerant in the air. The meter will let you know that the zeroing was successful by a quick flash of the zeroing LED. DR82 does not zero automatically while MZERO is displayed and will continue to alarm and display the relative leak size. But its nothing to make you not buy this product. The ruggedized construction stands up to abuse most other leak detectors can't handle. Find leaks in noisy environments, Mute: Turn off the sound when you don't want anyone to hear what you're doing, Magnetic Hanger. Filter system helps protect the sensor from moisture and other contaminants. replacement parts (model RFL2) are available fromFieldpiece. 8-hour Battery Charge. If not, the filtered tip may need to be replaced. Red light flashes, audible alarm triggers, and the display indicates the relative gas concentration. Less than 4 hours with either supplied charger, 32F (0C) to 104F It puts hundreds of thousands of products in the palm of yourhand! The large Li-ion rechargable battery provides over 10 hours of continuous operation and is convenient to charge via USB-C. It detectsa CHANGE in concentration, so the wand must keep moving. Fieldpiece Infrared Refrigerant Leak Detector - SRL2K7, *If you are searching for a brand specific cylinder P/N# type it in the search box above, or navigate to the calibration section of your instrument brand, Fieldpiece Heated Diode Refrigerant Leak Detector - SRL8, Fieldpiece Heated Diode Refrigerant Leak Detector - DR58, Fieldpiece Infrared Refrigerant Leak Detector - DR82, 7.4VDC(nominal), rechargeable lithium Do not use this device in a combustible gas atmosphere or with A3 refrigerants such as R-290, propane or R-600, isobutane. The ergonomic design fits naturally in your hand. The screen displays the leak size indicator and an easy-to-read bar graph. Audible/Visual Alarm. I have actually reviewed several refrigerant leak detectors from Fieldpiece, including the SLR2 and the SLR8. Turn the beep on or off - you decide. Like any other product, the Fieldpiece DR82 Infrared Refrigerant Leak Detector has its fair share of weaknesses. You will be required to provide your certificate number or declare the item will be resold to an EPA certified technician on certain types of Refrigerant. Ruggedized boot and it fit's in your hand. Sensitivity (H/M/L/T)DR82 starts up in high sensitivity (H) which is recommended for most situations. I checked their history, and I find it inspiring. State laws vary. 2. A quick andautomatic 30 second self-calibration upon power-upensures optimal performance. This means you might have to invest in another product. The eight segment LED display indicates the. The Fieldpiece DR82 is a compact device with a rugged outer shell, which is yellow. Begin searching for the leak source. All Rights Reserved. Peters MO 63304, SRL8 Fieldpiece Heated Diode Refrigerant Leak Detector, Booster Pacs - Jump Starters - Portable Power Supplies, Commercial Jump Starting Equipment Repair Parts. Please note that Environmental Protection Agency law requires certain individuals to be licensed before purchasing some refrigerants. This includes the leak size indicator, bar graph, lighted LED tip, and an audible beep. Conversely, stopping at or moving away from the leak source will not trigger a response.Press MANUAL/AUTO >1 second to toggle manual zero mode (MZERO). The manufacturer also provides replacement filters, which protect the sensor from dirt and moisture. Turn the beep on or off - you decide, 15-hour Battery Charge. SRL2 testing an A-coil in an evaporator, 1/4 from the line. RT100G Refrigeration Technologies Big Blu Leak Detector Bubbles 1 Gal. able sensitivity set-tings, keeping nui-sance tripping to aminimum. When it gets wet, it constricts flowof air and it will have to be replaced. Turning the PEAK function off will clear the peakchange. This leak detector is warranted against defects in material and workmanship for one year from date of purchase from an authorized Fieldpiece dealer. Something went wrong. The product you purchase comes with a user manual, which you can also find and download on their website. View cart for details. With DR82 set to high sensitivity (H), remove the cap and wave the tip over the cap. Compact and rugged, the DR82 Infrared Refrigerant Leak Detector helps you find leaks fast in the field. Not nearly as good at finding small leaks as The Fieldpiece heated diode leak detector but this one has a much longer sensor life and is less cross sensitive. Although its expensive, you are sure that you will be using this product for so many years without needing a replacement. When leaks are difficult to pinpoint due to excess triggering or sensor saturation, press SENSITIVITY to cycle to another sensitivity (Medium/Low/Turbo). Red Leak Indicator LEDIn most situations, the red LED at the tip is easier to monitor than the display. When in the TURBO mode the first green LED on. Move tip away from alarm location for a few seconds to clear the sensor. Best to have both, Verified purchase: Yes | Condition: Pre-owned. Five filtered tips (RFT6) are included. This feature is activated by pressing thePEAK button four times in succession, and can onlybe activated while on the high(H) sensitivity level. Good battery life. The main advantages of theFieldpiece IR sensor are that its sensitivity will remain the same over the life of the instrument, the sensor will last the lifetime of the instrument, it will not trigger on humidity or on oil, and it has nearly the same sensitivity to most refrigerants.The main disadvantage of infrared sensors is their sensitivity to mechanical disturbances. The sensor is connected to the body at the other end of the snout. TheSRL2 also has a mute button and a peak hold func-tion. ambient air, the lower the sensitivity setting shouldbe to minimize false trips. Apart from leak detectors, other products they produce include manometers, combustion detectors and checkers, electrical meters, scales, and digital manifolds, among other products. Doesn't trigger on oil or moisture like other types of detectors. Magnetic Hanger. The source ofthe leak will be near the midpoint between thetwo noted spots of indication. The higher the number, the higher the concentration of gas being measured and the closer you are to the exact leak location. The 10 year infrared (IR) sensor detects all HFC, HCFC, CFC, HFO, and blends. For instance, the sensors life on this product is 10 years. We will provide an in-depth review of this infrared refrigerant leak detector in this article. You can then confirm the leakage by first moving away from the suspected area. If its dirty, throw it away and insert a new one. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Its charge will last for days before you have to recharge it. SRL2 will strobe, and the audio detection sound willbe a solid tone. Keep the tip moving along refrigerant lines at a, 3. The PEAK LED will light when PEAK func-tion is on. Logos and Trademarks are the property of their respective owners. You can use the zero button to manually or automatically return to zero calibration. Ideally, you want to move the detector at about 1-3 inches per second. Handle with carewhen in TURBO mode. Fieldpiece DR82 Infrared Refrigerant Leak Detector, benefits that a quality infrared leak detector, head over to the products Amazon buy page. The eight-hour battery life lets you work all day before recharging and the included vehicle and wall chargers help you during overtime. Once a leak is detected, sweep the wand backover to pinpoint. And now it comes in kit form in a rugged, blow-mold case with all of the extras. It auto zeros every two seconds until a leak triggers the sensor. Degradation (30%) after 500 Sealed sensor. The lowest-priced item that has been used or worn previously.The item may have some signs of cosmetic wear, but is fully operational and functions as intended. LDR-1QS VAPCO Regular Leak Detector Bubbles Qt. We do not directly sell any products or refrigerants, but rather provide information, knowledge, and explanations to the consumer. What are some of the things I love about the Fieldpiece DR82 Leak Detector? Heated diode and corona discharge units tend to degrade or fail when they come in contact with high concentrations of refrigerant or touch liquid. The large bars on the backlit LCD are easy to see in bright sunlight or low light, and the numerical value provides an extra digit of resolution. Advantages Over Other Refrigerant Leak Detectors, Century Tool & Equipment4013 S. Old Hwy 94St. extremely sensitive and will more easily trigger onabrupt or violent motions as well as very smallchanges in refrigerant levels. I also tried dropping it to see what would happen. Pressing the MUTE button toggles the sound of, The PEAK function holds the highest change in. The most likely points for refrigerant leaks are at. We also want you to know that Refrigerant HQ is a participant in the Amazon Services LLC Associates Program and The E-Bay Partner Program. Return the tip back to, and past, the spot first. There are no questions or answers for this item. For instance, if you are in a noisy dark room, you can rely on the LED light tip. While using this product, I noted that this leak detector took about 20 to 30 seconds to calibrate back to zero or warm-up. Use a refrigerant tank and a cap to check if your DR82 is detecting refrigerant properly. Now let's dive in a bit to the operation process. Triggers on all CFCs, HFCs, HCFCs and blends. Tightly cap a refrigerant tank port to seal it. | LearnMore, First inStock our scannable label program makes it easy to stock your shop with FirstSupply! line. the soldered joints in refrigerant lines and changesin cross section or direction of these lines. Why? The 15-hour battery life lets you work all day and then some before recharging. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect. The included vehicle and wall chargers help you during overtime. (40C) at <75%RH (non-condensing), Triggers on all CFCs, HFCs, HCFCs and blends.ABMK3_w_SRL2. degree of change in refrigerant concentration. LD-CS JB Industries Leak Detector Carrying Case ONLY, LDA1000UV CPS Automotive Electronic Refrigerant Leak-Seeker. Return tip back to suspected leak, looking for the highest value. Unlike conventional leak detectors, you have full control with both an automatic (AZERO) and manual (MZERO) zero mode. Lights when approximately 1 DO NOT use the SRL2 without the proper fil-. Additionally, infrared technology can find even the most minor leaks in any joint or coil. Because theSRL2 detects change, there is a specific double-pass method used to find leaks. Ensure that you examine it (the filter) before using it. This item may be a floor model or store return that has been used.See details for description of any imperfections. They aspire to provide tools that make it easier for these professionals to work in various spaces. 43474-1, 4.9 out of 5 stars based on 14 product ratings, 4.5 out of 5 stars based on 168 product ratings, 4.6 out of 5 stars based on 149 product ratings, 5.0 out of 5 stars based on 1 product rating, 4.9 out of 5 stars based on 8 product ratings. To turn on/off the SRL2 press and hold the. 20122022, manualsdir.comAll rights reserved. The filter blocks moisture and other contaminants. The leak detector uses a lithium-ion rechargeable battery. Weighs 14-oz. Comment document.getElementById("comment").setAttribute("id","acea3960a75138a3967b4e1e90dfa2ce");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. You may need to be within 1/4 (0.63cm) ofa small leak to detect it. Everything was still intact. To recharge it, attach a USB-C cable (similar to the one you use to charge your phone) to the charging port located at the bottom of the device. Wait for the leak detector to return to zero and move towards the leakage again. Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. Sprayer 32 oz. UV dyes can take several hours to travel through a running system and can degrade system components. Its disadvantages are that the sensor becomes less sensitive over life, eventuallyneeding replacement and it is more sensitive tosome refrigerants than others. The magnetic hanger helps keep the detector out of the way when repairing a leak, but visible enough so you won't leave it on the job. Non-conductive, Sturdy Probe. charge/discharge cycles or two years, whichever Lets get right into it. To maximize battery life, minimize time spent at 100% full or 0% full.FILTER REPLACEMENT: The hydrophobic filter is built into the replaceable tip and should be replaced periodically to maximize sensor life and performance. Find leaks in noisy environments. By the way, the manufacturer provides a portable charger that you can use in your car and at home. Note that the unit can detect up to 0.03 ounces per year. The MUTE and ZEROing functions allow you to work the way you want to work.

Totalboat Epoxy Primer, List Of Over Voltage Protection Devices, Under Armour Charged Assert 9 4e, Sam's Club Plastic Shot Glasses, Elizabeth Craft Designs Planner Essentials 42,